ORIGINAL ARTICLE
Year : 2012  |  Volume : 2  |  Issue : 1  |  Page : 38-44

Evaluation of Dot-ELISA and enzyme-linked immuno-electrotransfer blot assays for detection of a urinary hydatid antigen in the diagnosis of cystic echinococcosis


1 Department of Microbiology, Sree Ramasamy Memorial Medical College Hospital and Research Centre, Potheri, Sri Ramaswamy Memorial University, Kattankulathur, Tamilnadu, India
2 Department of Microbiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Pondicherry, India

Correspondence Address:
Subhash Chandra Parija
Department of Microbiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Pondicherry
India
Login to access the Email id


DOI: 10.4103/2229-5070.97238

PMID: 23508649

Rights and Permissions

Background: Several serological assays are used for detection of a hydatid antigen in serum for diagnosis of cystic echinococcosis (CE). However, it requires technical expertise and is associated with the risk of acquiring blood-borne infections. Of late, interests have been shifted to other body fluids like urine, saliva, tear drops as alternate specimens in the diagnosis of CE. Aim: The aim of the study was to evaluate the dot enzyme-linked immunosorbent assay (Dot-ELISA) and electro-immunotransfer blot (EITB) for detection of a hydatid antigen in the urine for diagnosis of CE. Materials and Methods: 100 ml of urine samples were collected from the patients with confirmed CE (n=30), patients with suspected CE (n=30), patients with other diseases (n=30) and healthy controls (n=30). A hydatid antigen in urine was detected by Dot-ELISA and EITB using only polyclonal antibodies raised against a complete homogenate hydatid (CHH) antigen in rabbits. Results and Conclusions: The Dot-ELISA using polyclonal antibodies showed a sensitivity of 53.33% and specificity of 96.66%, whereas EITB showed a sensitivity of 46.66%. The Dot-ELISA and EITB employing polyclonal antibodies showed no significant difference in sensitivity (P=0.426). Hence, the Dot-ELISA being a simple procedure can be used for detection of a hydatid antigen in urine for diagnosis of CE.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2602    
    Printed120    
    Emailed0    
    PDF Downloaded188    
    Comments [Add]    
    Cited by others 4    

Recommend this journal